 Power entry modules without line filter www.schurter.com/pg05 IEC Appliance Inlet C14 with Circuit Breaker TA35 2-pole
635
C14
70 C
Description
-PanelMount: Snap-inversionfromfrontside -2Functions: ApplianceInlet,ProtectionclassI,CircuitbreakertypeTA35,2-pole -Quickconnectterminal6.3x0.8mm -Alternative:versionfor16A(20A)6136 -Substitutefortype7764
Characteristics
-Unwired -Switchnon-illuminatedorilluminated Thermaloverloadprotection -QualifiedforuseinequipmentaccordingIEC/EN60950
Other versions on request
Approvals
-Pre-wiredversion -Quick-connectterminals4.8x0.8mm -ProtectionclassII,70C
-VDELicenseNumber:40023066 -ULLicenseNumber:E96454
References Weblinks
GeneralProductInformation Approvals,RoHS,CHINA-RoHS,MatingConnectors,Distributor-StockCheck,Accessories
Technical Data
RatingsIEC RatingsUL/CSA DielectricStrength 10A/250VAC;50Hz 15A/250VAC;60Hz >2.5kVACbetweenL-N >3kVACbetweenL/N-PE (1min/50Hz) -25Cto60C fromfrontsideIP40acc.toIEC60529 Suitableforapplianceswithprotection class1acc.toIEC61140 Quickconnectterminals6.3x0.8mm Snap-in1.5/2/2.5/3mm Thermoplastic,black,UL94V-0 ApplianceInlet C14acc.toIEC/EN60320-1 UL498,CSAC22.2no.42(forcold conditions)pin-temperature70C,10A, ProtectionClass1 Acc.IEC/EN60934,UL1077,CSA 22.2no.235 2-polerockerswitch,illuminatedornonilluminated. ConditionalshortcircuitInc: 2000A
CircuitBreakers
AllowableOperationTemp. DegreeofProtection ProtectionClass Terminal PanelThicknesss Material:Housing
Connectors
635
www.schurter.com/pg05 Dimensions
30 10.6 31.8
Power entry modules without line filter
65.4mm
3.2 27.4
+0.20 0
58.8 x 27.2
65.4
6 max. R 0.2
R3
S 0.05 28.4
Diagrams
L 1) PE N N' P2
1) Line 2) Load
L' P1 2) PE'
TA35
Connectors
59
+0.20 0
Power entry modules without line filter www.schurter.com/pg05
ORDER CODE
Number of switched poles Number of protected poles 2-pole 1
LINE
635
Table 1 Selection for type TA35 Order example
2
LINE
LOAD
LOAD
TA35-
CBD
W
F
120
C0
Switch
without illumination illuminated 240 V 120 V
CBT
CBD No other features
Switch
C12 C14
C32 C34
Other versions on request
Colours
Switch front W B 3 4 6 black black black black black Rocker
non-illuminated illuminated
white black - - -
- - red transparent green transparent orange transparent
Other colours on request
Rocker legend
Surface F H K L embossed printed printed printed Illustration
0 l
Colour of print
OFF OFF
ON
white black white black
ON l l
M printed
Other legends on request
Position of the rocker legend e.g. F
0
0
Rated current In (A)
In 1,0 2,0 4,0 5,0 6,0 Code J10 J20 040 050 060 In 8,0 10,0 12,0 15,0 Code 080 100 120* 150*
Other rated currents on request
*) UL / CSA only
Connectors
3
635
www.schurter.com/pg05
Technical data (continued) Circuit breaker
Tripping characteristics In < 3 A
[ min ] [ sec ] 10'000
Type p Rated current Ambient temp. TA35 <3A (TC-1, TC-2) +23 C
Power entry modules without line filter
Tripping characteristics In > 3 ... 15 A
[ min ] [ sec ] 10'000
Type Rated current Ambient temp. TA35 > 3-15A (TC-1, TC-2) +23 C
60 30 20 10 5 200 100 1 50 2000 1000 500
60 30 20 10 5 200 100 1 50 2000 1000 500
20 10 5 2 1 0,5 Tr ipping time
Tr ipping time
20 10 5 2 1 0,5 0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ]
0,3 0,2 0,1 1,05 1,35 2 3 4 5 8 10 Multiple of rated current [ x In ]
The above tripping characteristics apply to symmetrical overloads on the two poles. At asymmetric overloads on two pole types the tripping current will be increased by factor 1.05 (TC-2).
Effect of ambient temperature
The unit is calibrated for an ambient temperature of +23 C. To determine the rated current for lower or higher ambient temperature, use a correction factor from the table below. * Ambient temperature [C] -25 -20 0 +23 +40 +50 +60 Correction factor 0.79 0.81 0.90 1.00 1.03 1.04 1.06 * Temperature must be measured at the rear of the breaker next to the terminals after equipment operating temperature has been reached. Example: Rated current at +23 C Ambient temperature Correction factor Chosen rated current at +60 C ambient temperature:
10 A +60 C 1.06 10 A x 1.06 = 10.6 A
Order code (Order example) Type Order code TA35
Wiring 1 wired 0 unwired
6135
CBDWF120C0 see table 1
.0210
Terminals 1 Quick connect 6.3 x 0.8 mm Mounting 2 Snap-in s = 1.5 mm 3 Snap-in s = 2.0 mm 4 Snap-in s = 2.5 mm 5 Snap-in s = 3.0 mm 0 Protection class 1
Please note that Schurter will establish an internal part number for logistics use in addition to the order code. The format of this internal part number is, for example: 6135.xxxx.xxxx
Packaging unit
40Pcs
Connectors
Power entry modules without line filter www.schurter.com/pg05 Accessories
Description
635
Assorted Covers Rear Cover 0859.0074
Cord retaining kits Cord retaining strain relief Flat head, A 4700.0001
Mating Outlets/Connectors
Category / Description
Appliance Outlet Overview complete IEC Appliance Outlet F, Screw-on Mounting, Front Side, Solder or Quick-connect Terminal IEC Appliance Outlet F, Snap-in Mounting, Front Side, Solder or Quick-connect Terminal Appliance Outlet further types to 6135 4787 4788
Connector Overview complete IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Straight IEC Connector C15A, Rewireable, Angled IEC Connector C13, Rewireable, Angled IEC Connector C13, Rewireable, Angled Connector further types to 6135 Power Cord Overview complete Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13, Angled Power Cord with IEC Connector C13 Power Cord further types to 6135 0311 3011 3012 3013 3020 ... 0102 0102-G 0112 4012 4013 ...
Thespecifications,descriptionsandillustrationsindicatedinthisdocumentarebasedon Connectors currentinformation.Allcontentissubjecttomodificationsandamendments.
5


▲Up To Search▲   

 
Price & Availability of TA35-CBT6K060C0

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X